Usted esta en:
UTF
   
    Features
 
  • Universal temperature signal inputs Thermocouple - J, K, E, T, N, R, S, B, and RTD PT100Ω
  • 0.1% accuracy + 0.5°C
  • Wide auxiliary power range AC / DC 30-250V
  • User friendly and easily configured
 
 
Specification
  • Universal Input 

        UTF_cuadro2

  • Accuracy
    • 0.1% fs + 0.5°C ( TC / J K E T N )
    • 0.1% fs + 1.5°C ( TC / R S B )
    • 0.1% fs + 0.3°C( RTD )
  • Stability
    • TC : 0.05°C / °C- cjc @ 25°C ; RTD : 0.03°C / °C
  • Resolution in display
    • 0.1°C / °F, < 2000°C / °F ; 1°F, > 2000°F
    • Auto range
  • Input resistance
    • TC > 10MΩ
  • Display
    • 4-1/2 digits / red LED with super rate
  • Noise rejection
    • NMRR > 60dB ; CMRR > 120dB
  • Surge test
    • IEC 1000-4-11, 4KV
  • Dielectric strength
    • 2.5KV AC rms 1 minute, power to input
  • Off line and over range detection
    • "OFL" flickering in display
  • Operating condition
    • -10 to 55°C, 0-99% RH non-condensed, storage -25 to 70°C
  • Auxiliary power
    • AC / DC 30--250V < 3 watts, (40-70Hz for AC)